For this example I'm showing it with a 5V supply but note that you can use this with a 3.3v supply just as easily. In this configuration the analog voltage reading ranges from 0V (ground) to about 5V (or about the same as the power supply voltage).
+
Sur cet exemple utilise une tension d'alimentation de 5 Volts mais vous pourriez utiliser une tension de 3.3 volts tout aussi facilement.  
   −
The way this works is that as the resistance of the FSR decreases, the total resistance of the FSR and the pulldown resistor decreases from about 100Kohm to 10Kohm. That means that the current flowing through both resistors increases which in turn causes the voltage across the fixed 10K resistor to increase. Its quite a trick!
+
Dans cette configuration, la tension analogique lue varie entre 0V (la masse/GND) jusqu'a environ 5V (la même tension que la tension d'alimentation).
 +
 
 +
Voici comment cela fonctionne:
 +
 
 +
Lorsque l'on presse le FSR, la résistance du senseur FSR diminue. La résistance totale FSR + résistance pull-down diminue également (ordre de grandeur de 100Kohm à 10Kohm). Cela signifie que le courant circulant dans le circuit FSR + Résistance PullDown augmente. En conséquence, la chute de tension aux bornes de la résistance '''fixe''' Pull-Down (10KOhm) augmente. Voila l'astuce!
    