Modifications

Sauter à la navigation Sauter à la recherche
Ligne 7 : Ligne 7 :  
* {{pl|2737|DINCASE-2R-BP3MOD}} : 2 relays backplane
 
* {{pl|2737|DINCASE-2R-BP3MOD}} : 2 relays backplane
 
* {{pl|151|TMP-DS18B20-WP}} : a DS18B20 OneWire temperature sensor.
 
* {{pl|151|TMP-DS18B20-WP}} : a DS18B20 OneWire temperature sensor.
 +
 +
A thermostat allows to define a temperature called the setpoint (eg: 25°C) and use an hysteresis range (EG: 2.5°C) to avoids continuous state change around the target temperature.
 +
 +
[[Fichier:heater-hysteresis.jpg]]
 +
 +
With the hysteresis, the heater starts heating from 25-2.5 = '''22.5°C''' and will stop heating when the temperature raised above 25+2.5 = '''27.5°C'''. The temperature will slowly decrease and the heater will start again when temperature falls under 22.5°C.
    
[[Fichier:MyDin-3modules.jpg|640px]]
 
[[Fichier:MyDin-3modules.jpg|640px]]
Ligne 14 : Ligne 20 :  
[[Fichier:MyDin-3modules-usage.jpg]]
 
[[Fichier:MyDin-3modules-usage.jpg]]
   −
#  * DS18B20 is connected to 1Wire port
+
* LED 1 reflect the Rel 1 state (so heating state).
−
#  * Rel 1 control the Heater
+
* LED 2 is lit while a FORCED forced is currently active
−
#  * LED 1 reflect the Rel 1 state.
+
* LED 3 will blink once to acknowledge T° increase.
−
#
+
* LED 4 will blink once to acknowledge T° decrease.
−
#  * Button 1 invert (force) the state of the relay.  
+
* BUTTON 1 reverse (force) the current state of the relay.<br />When the relay is ON then it switch it off.<br />When the relay is OFF then is switch it on.
−
#  * Forced state is canceled with the thermostat state reach the forced state
+
* BUTTON 2 cancel the forced state.
−
#  * Forced state is canceled when the button 2 is pressed.
+
* BUTTON 3 will decrease the setpoint T° of 1 degree.  
−
#  * LED2 is lit while a forced state do applies
+
* BUTTON 4 will increase the setpoint T° of 1 degree.
−
#  * button 3 will decrease the setpoint T°. Led 3 will blick once to acknowledge.
+
 
−
#  * button 4 will increase the setpoint T°. Led 4 will blink once to acknowledge.
+
Current temperature, setpoint temperature and relay state is displayed in the REPL session.
 +
 
 +
{{underline|'''Important remark''':}}<br />
 +
Forced state is canceled when the temperature reach the setpoint temperature corresponding the forced state.
 +
 
 +
Let say that
32 908

modifications

Menu de navigation