Ligne 46 : |
Ligne 46 : |
| </font> | | </font> |
| | | |
− | == Hardware Diagram == | + | == Détails techniques == |
| [[File:L298N_Descr.jpg]] | | [[File:L298N_Descr.jpg]] |
| | | |
| {| border="1" class="wikitable" | | {| border="1" class="wikitable" |
| |- | | |- |
− | | width="150px" align="center" | '''Port name''' | + | | width="150px" align="center" | '''Nom du connecteur''' |
| | width="100px" align="center" | '''Direction''' | | | width="100px" align="center" | '''Direction''' |
| | width="500px" align="center" | '''Description''' | | | width="500px" align="center" | '''Description''' |
− | | width="200px" align="center" | '''Usage''' | + | | width="200px" align="center" | '''Utilisation''' |
| |- style="font-size: 90%" | | |- style="font-size: 90%" |
| | align="center" | '''VMS GND''' | | | align="center" | '''VMS GND''' |
| | align="center" | / | | | align="center" | / |
− | | align="center" | connect to external power supply(6V~35V) | + | | align="center" | Connecté à l'alimentation externe(6V~35V) |
− | | rowspan="13" align="center" | ENA(ENB) connected to H state will enable MOTORA(MOTORB) IN1(IN3) connected to 5V and IN2(IN4) to GND MOTORA(MOTORB) will move clockwise IN1(IN3) connected to GND and IN2(IN4) to 5V MOTORA(MOTORB) will move Anti-clockwise if you cwant to control speed you can connect the ENA(ENB) to PWM. | + | | rowspan="13" align="center" | ENA(ENB) raccordés à un niveau haut (HIGH) activera MOTORA(MOTORB). <br /> |
| + | IN1(IN3) raccordés à 5V et IN2(IN4) a GND MOTORA(MOTORB) tournera dans le sens horlogique.<br /> IN1(IN3) raccordés à GND et IN2(IN4) à 5V MOTORA(MOTORB) tournera dans le sens Anti-horlogique.<br />Si vous voulez contrôler la vitesse, vous pouvez connecter ENA(ENB) sur une sortie PWM. |
| |- style="font-size: 90%" | | |- style="font-size: 90%" |
| | align="center" | '''ENA''' | | | align="center" | '''ENA''' |
− | | align="center" | Input | + | | align="center" | Entrée |
− | | align="center" | TTL Compatible Enable Input:the L state disables the bridge A | + | | align="center" | Compatible TTL, '''peut donc être utilise directement avec Arduino'''.<br />Entrée "Enable": un niveau bas LOW désactive le Pont A |
| |- style="font-size: 90%" | | |- style="font-size: 90%" |
| | align="center" | '''IN1''' | | | align="center" | '''IN1''' |
− | | align="center" | Input | + | | align="center" | Entrée |
− | | align="center" | TTL Compatible Inputs of the Bridge A | + | | align="center" | Compatible TTL. Entrée de commande de sens du pont A. |
| |- style="font-size: 90%" | | |- style="font-size: 90%" |
| | align="center" | '''IN2''' | | | align="center" | '''IN2''' |
− | | align="center" | Input | + | | align="center" | Entrée |
− | | align="center" | TTL Compatible Inputs of the Bridge A | + | | align="center" | Compatible TTL. Entrée de commande de sens du pont A. |
| |- style="font-size: 90%" | | |- style="font-size: 90%" |
| | align="center" | '''ENB''' | | | align="center" | '''ENB''' |
− | | align="center" | Input | + | | align="center" | Entrée |
− | | align="center" | TTL Compatible Enable Input:the L state disables the bridge B | + | | align="center" | Compatible TTL.<br />Entrée "Enable": un niveau bas LOW désactive le Pont B |
| |- style="font-size: 90%" | | |- style="font-size: 90%" |
| | align="center" | '''IN3''' | | | align="center" | '''IN3''' |
− | | align="center" | Input | + | | align="center" | Entrée |
− | | align="center" | TTL Compatible Inputs of the Bridge B | + | | align="center" | Compatible TTL. Entrée de commande de sens du pont B. |
| |- style="font-size: 90%" | | |- style="font-size: 90%" |
| | align="center" | '''IN4''' | | | align="center" | '''IN4''' |
− | | align="center" | Input | + | | align="center" | Entrée |
− | | align="center" | TTL Compatible Inputs of the Bridge B | + | | align="center" | Compatible TTL. Entrée de commande de sens du pont B. |
| |- style="font-size: 90%" | | |- style="font-size: 90%" |
− | | align="center" | '''M)TORA''' | + | | align="center" | '''MOTORA''' |
− | | align="center" | Output | + | | align="center" | Sortie |
− | | align="center" | Output of the Bridge A | + | | align="center" | Sortie du pont A. Commande en puissance du Moteur A |
| |- style="font-size: 90%" | | |- style="font-size: 90%" |
| | align="center" | '''MOTORB''' | | | align="center" | '''MOTORB''' |
− | | align="center" | Output | + | | align="center" | SORTIE |
− | | align="center" | Output of the Bridge B | + | | align="center" | Sortie du pont A. Commande en puissance du Moteur B |
| |- style="font-size: 90%" | | |- style="font-size: 90%" |
| | align="center" | '''CSA(CSB)''' | | | align="center" | '''CSA(CSB)''' |
| | align="center" | / | | | align="center" | / |
− | | align="center" | use for testing electric current of Bridge A(Bridge B) | + | | align="center" | Broches "Current Sensor" pour le Pont A et B.<br />Est utilisé pour tester le courant électrique qui traverse le pont A (pont B) |
| |- style="font-size: 90%" | | |- style="font-size: 90%" |
| | align="center" | '''UR1 UR2 UR3 UR4''' | | | align="center" | '''UR1 UR2 UR3 UR4''' |
| | align="center" | / | | | align="center" | / |
− | | align="center" | pull-up resistor | + | | align="center" | Résistance pull-up |
| |- style="font-size: 90%" | | |- style="font-size: 90%" |
| | align="center" | '''5V +5V''' | | | align="center" | '''5V +5V''' |
| | align="center" | / | | | align="center" | / |
− | | align="center" | 5V output | + | | align="center" | Sortie 5V |
| |- style="font-size: 90%" | | |- style="font-size: 90%" |
− | | align="center" | '''5V Chip Enable Jumper''' | + | | align="center" | '''Jumper activant le régulateur 5V''' |
| | align="center" | / | | | align="center" | / |
− | | align="center" | if connected,5V chip will work. | + | | align="center" | ''5V Chip Enable Jumper''. Le régulateur 5 volts est activé sur le jumper est connecté. |
− | | |
| |} | | |} |
| | | |