Mydin-UseCase-Basic-Thermostat

De MCHobby - Wiki
Sauter à la navigation Sauter à la recherche

Basic Thermostat

This project implements a basic temperature control system from a 3 modules MyDin made of:

 

The temperature sensor takes the room temperature and the heater is controled by the relay 1.

 

  • LED 1 reflect the Rel 1 state (so heating state).
  • LED 2 is lit while a FORCED forced is currently active
  • LED 3 will blink once to acknowledge T° increase.
  • LED 4 will blink once to acknowledge T° decrease.
  • BUTTON 1 reverse (force) the current state of the relay.
    When the relay is ON then it switch it off.
    When the relay is OFF then is switch it on.
  • BUTTON 2 cancel the forced state.
  • BUTTON 3 will decrease the setpoint T° of 1 degree.
  • BUTTON 4 will increase the setpoint T° of 1 degree.

Current temperature, setpoint temperature and relay state is displayed in the REPL session.

Hysteresis

A thermostat allows to define the target temperature called the setpoint (eg: 25°C) and use an hysteresis range (EG: 2.5°C) to avoids continuous state change around the target temperature.

 

With the hysteresis, the heater starts heating from 25-2.5 = 22.5°C and will stop heating when the temperature raised above 25+2.5 = 27.5°C. The temperature will slowly decrease and the heater will start again when temperature falls under 22.5°C.

Forced Mode

Lets say

Forced state is canceled when the temperature reach the setpoint temperature corresponding the forced state.

Let say that