== The temperature of my thermocouple seems to be backwards! ==
+
== La température de mon thermocouple semble inversée! ==
  
{{bloc-etroit|text=If I heat up the probe the reported temperature goes down
+
{{bloc-etroit|text=La température du thermocouple diminue lorsque je je le chauffe!.
This is likely caused by the thermocouple wires being labled incorrectly. Try swapping the two thermocouple leads, even if yellow and red wires are in the right slots - we've seen some thermocouple where the wire colors are wrong.}}
+
 
 +
Cela arrive lorsque les fils du thermocouple sont mal codifiés (libellés). Essayez d'inverser le raccordement du thermocouple sur votre amplificateur.... même sur le fil rouge (red) et jaune (yellow) sont correctement branchés - nous avons eu l'occasion de rencontrer des thermocouple avec une codification de couleur inversée.}}
  
 
== My MAX31855 output is really unstable and noisy ==
 
== My MAX31855 output is really unstable and noisy ==

Version du 14 août 2013 à 10:40


MCHobby investit du temps et de l'argent dans la réalisation de traduction et/ou documentation. C'est un travail long et fastidieux réalisé dans l'esprit Open-Source... donc gratuit et librement accessible.
SI vous aimez nos traductions et documentations ALORS aidez nous à en produire plus en achetant vos produits chez MCHobby.

La température de mon thermocouple semble inversée!

La température du thermocouple diminue lorsque je je le chauffe!.

Cela arrive lorsque les fils du thermocouple sont mal codifiés (libellés). Essayez d'inverser le raccordement du thermocouple sur votre amplificateur.... même sur le fil rouge (red) et jaune (yellow) sont correctement branchés - nous avons eu l'occasion de rencontrer des thermocouple avec une codification de couleur inversée.

My MAX31855 output is really unstable and noisy

If I touch or move the probe the temperature output goes crazy The MAX31855 is surprisingly sensitive, we've found a good way to fix this is to place a 0.01uF to 0.1uF capacitor across the thermocouple leads (that is, place the capacitor into the blue terminal block, or solder to the bottom as shown below).

Thermocouple-FAQ-01.jpg

My thermocouple output has an offset

I have multiple thermocouples and they dont 'agree' on a temperature

K thermocouples are not precision temperature measurement devices! There will be offsets & differences between thermocouples. Most thermocouple thermometers have the offset corrected in software which is what we suggest. For precision temperature measurement, we suggest a 1% Thermistor.

How can I connect multiple thermocouples?

You can connect as many MAX31855's as you have pins. Simply share the CLK and DO pins of all the breakouts and have a unique CS pin for each one

Then you can create new thermocouples using the following style:

Adafruit_MAX31855 thermocouple1(thermoCLK, thermoCS1, thermoDO);
Adafruit_MAX31855 thermocouple2(thermoCLK, thermoCS2, thermoDO);
Adafruit_MAX31855 thermocouple3(thermoCLK, thermoCS3, thermoDO);

Source: Thermocouple

Tutoriel créé par LadyAda pour AdaFruit Industries.

Traduit par Meurisse D. pour MCHobby.be

Traduit avec l'autorisation d'AdaFruit Industries - Translated with the permission from Adafruit Industries - www.adafruit.com

Toute référence, mention ou extrait de cette traduction doit être explicitement accompagné du texte suivant : «  Traduction par MCHobby (www.MCHobby.be) - Vente de kit et composants » avec un lien vers la source (donc cette page) et ce quelque soit le média utilisé.

L'utilisation commercial de la traduction (texte) et/ou réalisation, même partielle, pourrait être soumis à redevance. Dans tous les cas de figures, vous devez également obtenir l'accord du(des) détenteur initial des droits. Celui de MC Hobby s'arrêtant au travail de traduction proprement dit.