Ligne 18 : Ligne 18 :
 
[[Fichier:SBK-unexpected-data-02.png]]
 
[[Fichier:SBK-unexpected-data-02.png]]
  
A close inspection reveal that "180" value is the value of an iteration.
+
A close inspection reveal that "180" value is not a temperature but the next iteration number.
  
 
[[Fichier:SBK-unexpected-data-03.png]]
 
[[Fichier:SBK-unexpected-data-03.png]]
  
 
{{SBK-TRAILER}}
 
{{SBK-TRAILER}}

Version du 6 juillet 2024 à 22:50

Forewords

The SBK Datalogger generates CSV files that can be imported into spreadsheet (see this tutorial on Spreadsheet usage).

Upon condition, charting may reveal few data deviating from standard/common values.

This tutorial shows: why it happens, how to identify the data, how to fix it and what to do to avoids such situation.

The unexpected data

Drawing the data of the temperature sensor (content of the CSV) reveal an unexpected value.

SBK-unexpected-data-01.png

By exploring the data, we can locate that value of 180 °C.

SBK-unexpected-data-02.png

A close inspection reveal that "180" value is not a temperature but the next iteration number.

SBK-unexpected-data-03.png


Written by Meurisse D. for MCHobby


MCHobby investit du temps et de l'argent dans la réalisation de traduction et/ou documentation. C'est un travail long et fastidieux réalisé dans l'esprit Open-Source... donc gratuit et librement accessible.
SI vous aimez nos traductions et documentations ALORS aidez nous à en produire plus en achetant vos produits chez MCHobby.